CE Certification Accuracy's 2.5 Inch SF6 Gas Density Monitor for Leak Detection and Gas Monitoring Systems Manufacturer, Suppliers

SF6 Density Monitor is a precision instrument designed to monitor the density of SF6 gas in high-voltage electrical equipment, featuring automatic temperature compensation, dual alarm and lockout functions, and wide application in GIS, circuit breakers, and transformers.

The SF6 Density Monitor  is a critical protective device used in high-voltage power systems where sulfur hexafluoride (SF6) gas serves as both insulating and arc-quenching medium. Due to its excellent dielectric strength and thermal stability, SF6 gas is widely applied in switchgear, transformers, and gas-insulated substations (GIS). However, any leakage or pressure drop can compromise insulation performance and lead to equipment failure. Therefore, continuous monitoring of SF6 gas density—rather than just pressure—is essential for safe and reliable operation.

To address temperature-induced pressure fluctuations, modern SF6 density relays incorporate bimetallic temperature compensation mechanisms, ensuring that the displayed value reflects the equivalent pressure at 20°C regardless of ambient conditions.

Product Description

Product Specifications

Nominal size: 63mm
Scale range: -1 to 1 bar (customized)
Accuracy: 20℃: Class 1.0 or 1.6; -20℃ to +60℃: Class 2.5; -30℃ to -20℃: Class 3.0
Degree of protection: IP65
Ambient conditions: -30℃ to +60℃
Leakage rate: < 1*10-9 Pa.m3/s (Helium mass spectrometer)
Pressure connector: G1/4", NPT 1/4", M20*1.5 (customized)
Location: Center back
Electrical connection: Compact pluggable box with M20*1.5 cable gland
Cable size: 1.5mm; 2 recommended; 2.5mm maximum
Insulation properties: Insulation resistance >100 MΩ (500V DC); Withstand voltage 2kV, 50/60 Hz 1 min (to case)
Contact type: Pointer driven magnetic snap action signal contacts; 80%Ag, 20%Ni, 10μm Au plated
Contact ratings: 30W/50VA, 1A max; 220VDC/380V 50/60Hz max
Window: Safety glass
Weight: 0.5KG

Core Characteristics and Advantages

Temperature Compensation

Automatically adjusts for thermal effects using bimetal strips or digital sensors, providing stable readings at varying temperatures.

Dual Set Points

Configurable alarm and lockout contacts trigger signals when gas density drops below preset thresholds, enabling timely maintenance or system shutdown.

Robust Design

Available in all-stainless steel construction with optional oil filling for enhanced shock and vibration resistance.

Remote Monitoring Capability

Models with wireless transmission (e.g., LoRa) or RS485 output support integration into smart grid systems for real-time data access.

Typical Application Fields

High-Voltage Circuit Breakers Monitors SF6 levels during operation and triggers lockout if density falls below safety threshold.
Gas-Insulated Switchgear (GIS) Ensures long-term integrity of sealed compartments exposed to outdoor environments.
Transformers & Instrument Transformers Protects against internal faults caused by gas loss.

Frequently Asked Questions

What is the ingress protection level of this density monitor?
This product features an IP65 degree of protection, making it suitable for operation in demanding outdoor and industrial ambient conditions ranging from -30℃ to +60℃.
How does temperature compensation ensure accurate readings?
It utilizes built-in bimetal strips or digital sensors to automatically adjust for thermal expansion and contraction effects, delivering reliable and consistent gas density measurements regardless of ambient temperature changes.
What customizable connection options are available?
Pressure connectors can be customized with standard options including G1/4", NPT 1/4", and M20*1.5. Scale ranges (standard -1 to 1 bar) can also be tailored to specific operational requirements.
Can this gauge be integrated into smart grid or remote monitoring systems?
Yes, select models offer wireless transmission protocols such as LoRa or RS485 digital output, enabling seamless real-time data integration into smart grid management software.
What safety mechanisms trigger during a gas loss event?
The device features configurable dual set points (alarm and lockout contacts). When gas density drops below critical preset thresholds, signal contacts trigger immediate maintenance alerts or automatic system lockouts.
What is the maximum leakage rate and window material used?
The unit boasts an exceptionally low leakage rate of less than 1*10-9 Pa.m3/s (tested via Helium mass spectrometer) and is fitted with a durable safety glass window.